Tank Guard — Protective Water Tank Coating in Karachi
Tank Guard is a specialised protective coating designed for the internal surfaces of cold water storage tanks. Its bitumen-based formulation creates a protective barrier against corrosion while helping maintain the quality of stored water without tainting it.
Available in a glossy black finish, Tank Guard is formulated as a non-toxic, water-safe coating for cold water tanks. It provides a protective layer for tank interiors and can be applied using a brush, roller or spray equipment.
For other protective coating solutions, explore our range of industrial paints in Karachi.
Why Choose Tank Guard?
Water storage tanks require suitable internal protective coatings to help protect their surfaces against corrosion. Tank Guard provides a bitumen-based protective layer designed specifically for cold water tank interiors.
Its water-safe formulation, glossy finish and convenient application methods make it a practical coating option for cold water storage tank protection.
Key Features
- Corrosion Protection: Forms a protective barrier against corrosion on the internal surfaces of cold water tanks.
- Water-Safe Formulation: Described as a non-toxic coating that does not taint stored water.
- Bitumen-Based Composition: Formulated using specially graded bitumen in a solvent-based vehicle.
- Glossy Black Finish: Provides a uniform black protective coating.
- Multiple Application Methods: Can be applied using a brush, roller, conventional spray or airless spray.
- Self-Priming: The product itself serves as the primer, according to the technical specifications.
- Good Coverage: Theoretical spreading rate of approximately 9.5–11 m² per litre per coat.
Recommended Applications
Tank Guard is specially formulated for the internal surfaces of cold water storage tanks.
- Internal surfaces of cold water storage tanks
- Water storage tank interiors
- Metal water tank internal surfaces
- Suitable tank surfaces requiring protective bitumen-based coating
Before application, ensure that the tank surface is properly prepared, clean and suitable for the coating system.
Technical Information
- Product Type: Protective Bitumen-Based Coating
- Recommended Use: Internal Cold Water Tank Coating
- Colour: Black
- Finish: Gloss
- Vehicle: Specially Graded Bitumen in Solvent
- Appearance: Liquid
- Odour: Solvent
- Volume Solids: 45% ± 2%
- Flash Point: 34°C
- Theoretical Spreading Rate: 9.5–11 m² per litre per coat
- Recommended Coats: Two to Three
- Primer: Self-Priming
- Wet Film Thickness: 85 microns
- Dry Film Thickness: 38 microns
- Thinner: Suitable compatible thinner
- Tool Cleaning: Thinner or mineral spirits
- Shelf Life: 12 Months
Actual coverage may vary depending on application method, surface roughness, porosity and application losses.
Application Methods
Tank Guard can be applied using the following methods:
- Brush
- Roller
- Conventional spray
- Air-mix spray
- Airless spray
The recommended application system consists of two to three coats. The coating is self-priming, so a separate primer is not specified in the supplied technical datasheet.
Drying Time
Drying time depends on temperature, humidity and ventilation conditions.
- At 10°C: Approximately 14 hours to touch dry.
- At 20°C: Approximately 6 hours to touch dry.
- At 40°C: Approximately 3 hours to touch dry.
- Minimum Recoat Interval: 12 hours.
- Hard Dry: Approximately 24 hours.
These drying times assume proper ventilation. Actual drying and recoating times may vary depending on temperature, humidity and applied film thickness.
Surface Preparation and Application
Before applying Tank Guard, ensure that the internal tank surface is clean, dry and free from loose material and contaminants. Proper surface preparation helps achieve a consistent protective coating.
Recommended Application Process:
- Step 1 – Surface Preparation: Clean the tank’s internal surface and remove loose material, dust and contaminants.
- Step 2 – First Coat: Apply the first coat evenly using a suitable brush, roller or spray equipment.
- Step 3 – Recoating: Allow a minimum of 12 hours before applying the next coat, subject to actual drying conditions.
- Step 4 – Final Coats: Apply the recommended two to three coats to achieve the specified film thickness.
Apply at temperatures above 10°C. Do not apply when relative humidity exceeds 85% or when the temperature is below 5°C.
Clean-Up
Clean spills, spatters, hands and application equipment immediately after use with suitable thinner or mineral spirits. After cleaning spray equipment, flush it with mineral spirits to help prevent rusting. Follow appropriate safety recommendations when handling cleaning solvents.
Storage and Safety Precautions
- Store in a cool, dry and shaded place.
- Keep containers away from direct sunlight.
- Keep containers properly sealed when not in use.
- Do not mix with other paints, organic solvents or powder materials.
- Ensure proper ventilation during application and drying.
- Handle the product carefully and follow the safety instructions on the packaging.
- Do not take internally.
- Keep out of reach of children.
- Follow applicable safety regulations when handling solvents and application equipment.
Shelf Life: Up to 12 months under recommended storage conditions.
Buy Tank Guard in Karachi
Saify Paint House supplies specialised paints and protective coatings for residential, commercial and industrial applications across Karachi.
Visit our Badar Commercial store at Shop #2, Plot 31-E, 7th Street, DHA Phase 5, or our Gizri store at Shop #2, Al Raheem Center, Main Gizri, opposite Mubarak Masjid, DHA Karachi.
For Tank Guard pricing, packaging sizes and availability, contact our team on WhatsApp or call 0333-5843610.